Products

Flair S12

  • Reset Filter
  • Sectors

Designed specifically for subsurface rail applications.
  • Designed in accordance with fire precautions for subsurface rail stations (Section 12).
  • Complies with London Underground subsurface standard S1085 utilising low smoke, zero halogen cables and control gear.
  • Impact resistance rating: IK08 (5 joules of energy).
  • Ingress protection rating: IP65.
  • Suitable for ceiling or optional recessed mounting.
  • Extruded aluminium body and die cast end caps finished in matt silver polyester powder coat.
  • Toughened frosted glass diffuser held against silicone gasket by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back.
  • Version available with clear Glass diffuser and louvre with optical film.

Technical Information

615mm LONG
LED Temp Load Lum/lm Efficacy CRI Weight
FLR/2/1500NW/C48/S12F 4000K 15.5W 957 lm 62lm/W CRI>80 4.8kg
FLR/2/2000NW/C48/S12F 4000K 21W 1247 lm 59lm/W CRI>80 4.8kg
FLR/2/2500NW/C48/S12F 4000K 26.7W 1523 lm 57lm/W CRI>80 4.8kg
FLR/2/3000NW/C48/S12F 4000K 30.5W 1825 lm 60lm/W CRI>80 4.8kg
1215mm LONG
LED Temp Load Lum/lm Efficacy CRI Weight
FLR/4/3000NW/C48/S12F 4000K 28.1W 1981 lm 71lm/W CRI>80 8.7kg
FLR/4/4000NW/C48/S12F 4000K 35.6W 2602 lm 73lm/W CRI>80 8.7kg
FLR/4/5000NW/C48/S12F 4000K 49.6W 3204 lm 65lm/W CRI>80 8.7kg
FLR/4/6000NW/C48/S12F 4000K 57.8W 3566 lm 62lm/W CRI>80 8.7kg
1515mm LONG
LED Temp Load Lum/lms CRI Efficacy Weight
FLR/5/3750NW/C48/S12F 4000K 33.8W 2655 lm 78lm/W CRI>80 10.5kg
FLR/5/5000NW/C48/S12F 4000K 47.3W 3541 lm 75lm/W CRI>80 10.5kg
FLR/5/6250NW/C48/S12F 4000K 61W 4318 lm 71lm/W CRI>80 10.5kg
FLR/5/7500NW/C48/S12F 4000K 70.6W 4795 lm 68lm/W CRI>80 10.5kg

 

Fitting Options

Pure white finish replace C48 with C32
Section 12 clear glass with louvre & optical film replace S12F with S12C
Integral 3 hour duration emergency* add suffix /EM3
Self test 3 hour duration emergency* add suffix /EM3S
DALI 3 hour duration emergency* add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
Warm white LEDs (3000K) replace NW with WW
End entry(s) add suffix /H or /HH
Recessed  (includes 20mm flange all round, add 8mm to width and length shown). add suffix /R

*No emergency options available on all 2 foot (615mm) versions.

Robust linear fitting specialised for subsurface rail applications.


Sectors

Finishes


Downloads

Download PDF Download LDT Download BIM Download IES Specification Assists Installed Photos DOWNLOAD DofC