Products

Mission S12

  • Reset Filter
  • Sectors

Designed specifically for subsurface rail applications
  • Designed in accordance with fire precautions for subsurface rail stations (Section 12).
  • Complies with London Underground subsurface standard 1-085 utilising low smoke, zero halogen cables and control gear.
  • Suitable for surface mounting.
  • Extruded aluminium body and die cast aluminium end caps finished in pure white or matt silver polyester powder coat.
  • Toughened laminated glass diffuser held against silicone gasket by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back.

Lamp options

LAMP OPTIONS

GLASS DIFFUSER
353mm LONG
LED Lamps Temp Load Lum/lms Efficacy Weight
D599/1/1500NW/C32/S12X LED Array 4000K 15.4W 1512lms 98lm/W 3.4KG
D599/1/2500NW/C32/S12X LED Array 4000K 22.9W 2148lms 94lm/W 3.4KG
703mm LONG
LED Lamps Temp Load Lum/lms Efficacy Weight HT
D599/2/1500NW/C32/S12X LED Array 4000K 15.8W 1636lms 104lm/W 5.7KG HT50°
D599/2/2000NW/C32/S12X LED Array 4000K 19.2W 1996lms 104lm/W 5.7KG HT50°
D599/2/2500NW/C32/S12X LED Array 4000K 23.3W 2390lms 103lm/W 5.7KG HT50°
D599/2/3000NW/C32/S12X LED Array 4000K 27W 2695lms 100lm/W 5.7KG HT50°
1303mm LONG
LED Lamps Temp  Load Lum/lms Efficacy Weight HT
D599/4/3000NW/C32/S12X LED Array 4000K 28.4W 3433lms 121lm/W 9.9KG HT50°
D599/4/4000NW/C32/S12X LED Array 4000K 35.7W 4228lms 119lm/W 9.9KG HT50°
D599/4/5000NW/C32/S12X LED Array 4000K 43.2W 4988lms 115lm/W 9.9KG HT50°
D599/4/6000NW/C32/S12X LED Array 4000K 50.9W 5695lms 112lm/W 9.9KG HT50°
1603mm LONG
LED Lamps Temp Load Lum/lms Efficacy Weight HT
D599/5/3750NW/C32/S12X LED Array 4000K 34.5W 4294lms 124lm/W 14KG HT50°
D599/5/5000NW/C32/S12X LED Array 4000K 43W 5200lms 121lm/W 14KG HT50°
D599/5/6250NW/C32/S12X LED Array 4000K 53W 6260lms 118lm/W 14KG HT50°
D599/5/7500NW/C32/S12X LED Array 4000K 62.9W 7191lms 114lm/W 14KG HT50°

Fitting options

FITTING OPTIONS

Matt silver finish replace C32 with C48
Integral 3 hour duration emergency add suffix /EM3
Self test 3 hour duration emergency add suffix /EM3S
DALI 3 hour duration emergency add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
Warm white LEDs (3000K) replace NW with WW
For use with 50V or 110V ac/dc central battery systems add suffix /EV
240V changeover relay add suffix /ER
 *DALI cannot be combined with Emergency Options for 1ft and 2ft
*EM3D is not available on the 353mm or 703mm versions

Designed specifically for subsurface rail applications.


Sectors

Finishes


Downloads

Download PDF Download LDT Download BIM Specification Assists Case Study Installed Photos