  • Sectors

Designed specifically for subsurface rail applications
  • Designed in accordance with fire precautions for subsurface rail stations (Section 12).
  • Complies with London Underground subsurface standard 1-085 utilising low smoke, zero halogen cables and control gear.
  • Impact resistance rating: IK10 (20 joules of energy).
  • Ingress protection rating: IP65
  • Suitable for surface mounting.
  • Extruded aluminium body and die cast aluminium end caps finished in pure white or matt silver polyester powder coat.
  • Toughened laminated glass diffuser held against silicone gasket by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back.

Technical Information

GLASS DIFFUSER
353mm LONG
LED Temp Load Lum/lm Efficacy CRI Weight
D599/1/1500NW/C32/S12X 4000K 15.4W 1512 lm 98lm/W CRI>80 3.4kg
D599/1/2500NW/C32/S12X 4000K 22.9W 2148 lm 94lm/W CRI>80 3.4kg
703mm LONG
LED Temp Load Lum/lm Efficacy CRI>80 Weight HT
D599/2/1500NW/C32/S12X 4000K 15.8W 1636 lm 104lm/W CRI>80 5.7kg HT50°
D599/2/2000NW/C32/S12X 4000K 19.2W 1996 lm 104lm/W CRI>80 5.7kg HT50°
D599/2/2500NW/C32/S12X 4000K 23.3W 2390 lm 103lm/W CRI>80 5.7kg HT50°
D599/2/3000NW/C32/S12X 4000K 27W 2695 lm 100lm/W CRI>80 5.7kg HT50°
1303mm LONG
LED Temp  Load Lum/lm Efficacy CRI Weight HT
D599/4/3000NW/C32/S12X 4000K 28.4W 3433 lm 121lm/W CRI>80 9.9kg HT50°
D599/4/4000NW/C32/S12X 4000K 35.7W 4228 lm 119lm/W CRI>80 9.9kg HT50°
D599/4/5000NW/C32/S12X 4000K 43.2W 4988 lm 115lm/W CRI>80 9.9kg HT50°
D599/4/6000NW/C32/S12X 4000K 50.9W 5695 lm 112lm/W CRI>80 9.9kg HT50°
1603mm LONG
LED Temp Load Lum/lm Efficacy CRI>80 Weight HT
D599/5/3750NW/C32/S12X 4000K 34.5W 4294 lm 124lm/W CRI>80 14kg HT50°
D599/5/5000NW/C32/S12X 4000K 43W 5200 lm 121lm/W CRI>80 14kg HT50°
D599/5/6250NW/C32/S12X 4000K 53W 6260 lm 118lm/W CRI>80 14kg HT50°
D599/5/7500NW/C32/S12X 4000K 62.9W 7191 lm 114lm/W CRI>80 14kg HT50°

 

Fitting Options

Matt silver finish replace C32 with C48
Integral 3 hour duration emergency add suffix /EM3
Self test 3 hour duration emergency add suffix /EM3S
DALI 3 hour duration emergency add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
Warm white LEDs (3000K) replace NW with WW
For use with 50V or 110V ac/dc central battery systems add suffix /EV
240V changeover relay add suffix /ER
 *DALI cannot be combined with Emergency Options for 1ft and 2ft
*EM3D is not available on the 353mm or 703mm versions