Products

Tuscan S12

  • Reset Filter
  • Sectors

Specialised fitting designed for subsurface rail applications.
  • Designed in accordance with fire precautions for subsurface rail stations (Section 12).
  • Complies with London Underground subsurface standard 1-085 utilising low smoke, zero halogen cables and control gear.
  • Suitable for surface or recessed ceiling mounting.
  • Heavy gauge steel body finished in black polyester powder coat.
  • Toughened glass diffuser sealed into frame by silicone gasket and held in place by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back and ends, gaskets provided.

Lamp Options

GLASS DIFFUSER
700mm LONG
LED Lamps Temp Load Lum/lms Efficacy Weight
D880/2/1500NW/B/S12F LED Array 4000K 15W 1308lms 87lm/W 7KG
D880/2/2000NW/B/S12F LED Array 4000K 18W 1544lms 86lm/W 7KG
D880/2/2500NW/B/S12F LED Array 4000K 22W 1871lms 85lm/W 7KG
D880/2/3000NW/B/S12F LED Array 4000K 26W 2096lm 81lm/W 7KG
1300mm LONG
LED Lamps Temp Load Lum/lms Efficacy Weight
D880/4/2000NW/B/S12F LED Array 4000K 21W 1923lms 92lm/W 12KG
D880/4/3000NW/B/S12F LED Array 4000K 28W 2543lms 91lm/W 12KG
D880/4/4000NW/B/S12F LED Array 4000K 35W 3086lms 88lm/W 12KG
D880/4/5000NW/B/S12F LED Array 4000K 43W 3742lm 87lm/W 12KG
D880/4/6000NW/B/S12F LED Array 4000K 51W 4291lm 84lm/W 12KG
1600mm LONG
LED Lamps Temp Load  Lum/lms Efficacy Weight
D880/5/2500NW/B/S12F LED Array 4000K 27W 2404lms 89lm/W 15KG
D880/5/3750NW/B/S12F LED Array 4000K 35W 3179lms 91lm/W 15KG
D880/5/5000NW/B/S12F LED Array 4000K 44W 3858lms 88lm/W 15KG
D880/5/6250NW/B/S12F LED Array 4000K 54W 4678lms 86lm/W 15KG
D880/5/7500NW/B/S12F LED Array 4000K 63W 5240lms 83lm/W 15KG

Fitting Options

FITTING OPTIONS

Textured white finish replace B with W
Pure white finish replace B with C32
Integral 3 hour duration emergency add suffix /EM3
Self test 3 hour duration emergency add suffix /EM3S
DALI 3 hour duration emergency* add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
For 45° angled version replace D880 with D883
For 30/60° angled version replace D880 with D882
Recessed add suffix /R
Warm white LEDs (3000K) replace NW with WW
External Fixing Lugs add suffix /BR
1m Conduit and leads add suffix /1C
2m Conduit and leads add suffix /2C
For use with 50V or 110V ac/dc central battery systems add suffix /EV
240V changeover relay add suffix /ER

*For Tuscan D89 S12 version replace D88 with D89 * EM3D not available on all 2 foot (700mm) versions * External Fixing Lugs only available on D880 S12 fitting *1m Conduit and 2m Conduit only available on D880 S12 fitting