Products

Flair Angled S12

  • Reset Filter
  • Sectors

Design specifically for subsurface rail applications.
  • Designed in accordance with fire precautions for subsurface rail stations (Section 12).
  • Complies with London Underground subsurface standard S1085 utilising low smoke, zero halogen cables and control gear.
  • Impact resistance rating: IK08 (5 joules of energy)
  • Ingress protection rating: IP65
  • Suitable for surface mounting.
  • Versatile fitting with easy application and high LOR ratings.
  • Suitable for wall mounting.
  • Body finished in matt silver polyester powder coat.
  • Toughened frosted glass diffuser held against gasket by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back.
  • Version available with clear glass diffuser and louvre with optical film.

Technical Information

CLEAR DIFFUSER
615mm LONG
LED Temp Load Lum/lm Efficacy CRI Weight
FLRA/2/1500NW/C48/S12F 4000K 15.5W 957 lm 62lm/W CRI>80 4KG
FLRA/2/2000NW/C48/S12F 4000K 21W 1247 lm 59lm/W CRI>80 4KG
FLRA/2/2500NW/C48/S12F 4000K 26.7W 1523 lm 57lm/W CRI>80 4KG
FLRA/2/3000NW/C48/S12F 4000K 30.5W 1825 lm 60lm/W CRI>80 4KG
1215mm LONG
LED Temp Load Lum/lms Efficacy CRI Weight
FLRA/4/3000NW/C48/S12F 4000K 28.1W 1981 lm 71lm/W CRI>80 7.3KG
FLRA/4/4000NW/C48/S12F 4000K 35.6W 2602 lm 73lm/W CRI>80 7.3KG
FLRA/4/5000NW/C48/S12F 4000K 49.6W 3204 lm 65lm/W CRI>80 7.3KG
FLRA/4/6000NW/C48/S12F 4000K 57.8W 3566 lm 62lm/W CRI>80 7.3KG
1515mm LONG
LED Temp Load Lum/lm Efficacy CRI Weight
FLRA/5/3750NW/C48/S12F 4000K 33.8W 2655 lm 78lm/W CRI>80 8.9KG
FLRA/5/5000NW/C48/S12F 4000K 47.3W 3541 lm 75lm/W CRI>80 8.9KG
FLRA/5/6250NW/C48/S12F 4000K 61W 4318 lm 71lm/W CRI>80 8.9KG
FLRA/5/7500NW/C48/S12F 4000K 70.6W 4795 lm 68lm/W CRI>80 8.9KG

 

Fitting Options

Pure white finish replace C48 with C32
Section 12 clear glass with louvre and optical film replace S12F with S12C
Warm white LEDs (3000K) replace NW with WW
Integral 3 hour duration emergency* add suffix /EM3
Self test 3 hour duration emergency* add suffix /EM3S
DALI 3 hour duration emergency* add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
End entry(s) add suffix /H or /HH

* No emergency options available on all 2 foot (615mm) versions 

The /DALI and /DIM options are not available on all 2 foot (615mm) versions

Angled linear fitting specialised for sub surface rail applications.


Sectors

Finishes


Downloads

Download PDF Download LDT Download BIM Download IES Specification Assists Installed Photos DOWNLOAD DofC