Parkalux Angled vandal resistant luminaire is a hard wearing angled linear light fitting.
  • Impact resistance rating: IK14 (100 joules of energy).
  • Ingress protection rating: IP54.
  • Suitable for wall and cornice mounting.
  • Zinc-coated steel body finished in black polyester powder coat.
  • Polycarbonate diffuser held against gasket by tamperproof screws.
  • Electronic control gear on removable tray with fused plug & socket connector block.
  • Provision for conduit entry in back and at ends, gaskets provided.

Technical Information

L1245mm x W86mm x H86mm
LED, Opal Diffuser Temp Load Lum/lm Efficacy CRI Weight
D323/4/2000NW/XB 4000K 21.2W 2152 lm 101lm/W CRI>80 5.6kg
D323/4/3000NW/XB 4000K 28.3W 2829 lm 100lm/W CRI>80 5.6kg
D323/4/4000NW/XB 4000K 35W 3450 lm 99lm/W CRI>80 5.6kg
D323/4/5000NW/XB 4000K 42.7W 4062 lm 95lm/W CRI>80 5.6kg
D323/4/6000NW/XB 4000K 50.3W 4647 lm 92lm/W CRI>80 5.6kg
Emergency Output 4000K 583 lm
L1562mm x W90mm x H90mm
LED, Opal Diffuser Temp Load Lum/lm Efficacy CRI Weight
D323/5/2500NW/XB 4000K 26.1W 2790 lm 107lm/W CRI>80 7kg
D323/5/3750NW/XB 4000K 34.9W 3647 lm 105lm/W CRI>80 7kg
D323/5/5000NW/XB 4000K 43.7W 4458 lm 102lm/W CRI>80 7kg
D323/5/6250NW/XB 4000K 53.3W 5237 lm 98lm/W CRI>80 7kg
D323/5/7500NW/XB 4000K 62.2W 5919 lm 95lm/W CRI>80 7kg
Emergency Output 4000K 627 lm

Parkalux Angled contains a light source of energy efficiency class C (4000K) and class D (3000K).

Parkalux Angled LED Lifetime L70B10>110,000h (4000K), L70B10>100,000h (3000K) at 25oC ambient.

Parkalux Angled Driver Lifetime up to 100,000h at 25oC ambient.

Fitting Options

Textured white finish replace B with W
Titanium finish replace B with C49
Integral 3 hour duration emergency add suffix /EM3
Self test 3 hour duration emergency add suffix /EM3S
DALI 3 hour duration emergency add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Switch dimming add suffix /DIM
Blank ends add suffix /BE
For Network Rail specification add suffix /NET
Warm white LEDs (3000K) replace NW with WW
For use with 110V ac/dc central battery systems add suffix /EV
240V changeover relay add suffix /ER
Corridor function* add suffix /CF10
* CF10 option will only work if combined with an external presence detection sensor supplied by others