Tuscan 88 Angled vandal resistant luminaire is ideal for a variety of challenging lighting applications where a robust, weather proof fitting is required.
- Designed to resist extreme physical attack.
- Applications include subways, platforms and pedestrian walkways.
- Suitable for cornice mounting at either 45° or 30°/60° angles.
- Impact resistance rating: IK16 (150 joules of energy).
- Ingress protection rating: IP65.
- Heavy gauge steel body finished in black polyester powder coat.
- Opal polycarbonate diffuser held against gasket with tamperproof screws.
- Dummy bodies and infill panels available for continuous mounting, please contact technical sales.
- Electronic control gear on removable tray with fused plug & socket connector block.
- Provision for conduit entry in ends, gaskets provided.
Technical Information
The data below is for the 45° angled luminaire (D883). A 30°/60° angled luminaire is also available (D882). The lamp data is identical except that the weight of the 30°/60° angled luminaire (D882) is as follows: 700mm = 6kg, 1300mm = 10.6kg, 1600mm = 12.4kg.
L700mm x W158mm x H158mm | ||||||
LED, Opal Diffuser | Temp | Load | Lum/lm | Efficacy | CRI | Weight |
D883/2/1500NW/XB | 4000K | 15.6W | 1377 lm | 88lm/W | CRI>80 | 5.7kg |
D883/2/2000NW/XB | 4000K | 20.8W | 1801 lm | 87lm/W | CRI>80 | 5.7kg |
D883/2/2500NW/XB | 4000K | 26.8W | 2297 lm | 86lm/W | CRI>80 | 5.7kg |
D883/2/3000NW/XB | 4000K | 30.8W | 2567 lm | 83lm/W | CRI>80 | 5.7kg |
Emergency Output | 4000K | – | 457 lm | – | – | – |
L1300mm x W158mm x H158mm | ||||||
LED, Opal Diffuser | Temp | Load | Lum/lm | Efficacy | CRI | Weight |
D883/4/3000NW/XB | 4000K | 28.4W | 2804 lm | 99lm/W | CRI>80 | 10.1kg |
D883/4/4000NW/XB | 4000K | 38.8W | 3718 lm | 96lm/W | CRI>80 | 10.1kg |
D883/4/5000NW/XB | 4000K | 50.3W | 4616 lm | 92lm/W | CRI>80 | 10.1kg |
D883/4/6000NW/XB | 4000K | 58.4W | 5298 lm | 91lm/W | CRI>80 | 10.1kg |
Emergency Output | 4000K | – | 638 lm | – | – | – |
L1600mm x W158mm x H158mm | ||||||
LED, Opal Diffuser | Temp | Load | Lum/lm | Efficacy | CRI | Weight |
D883/5/3750NW/XB | 4000K | 34.8W | 3565 lm | 102lm/W | CRI>80 | 11.5kg |
D883/5/5000NW/XB | 4000K | 47.6W | 4681 lm | 98lm/W | CRI>80 | 11.5kg |
D883/5/6250NW/XB | 4000K | 62.5W | 5860 lm | 94lm/W | CRI>80 | 11.5kg |
D883/5/7500NW/XB | 4000K | 72.1W | 6520 lm | 90lm/W | CRI>80 | 11.5kg |
Emergency Output | 4000K | – | 588 lm | – | – | – |
Tuscan 88 Angled contains a light source of energy efficiency class C (4000K) and class D (3000K).
Tuscan 88 Angled LED Lifetime L70B10>110,000h (4000K), L70B10>100,000h (3000K) at 25oC ambient.
Tuscan 88 Angled Driver Lifetime up to 100,000h at 25oC ambient.
Fitting Options
Textured white finish | replace B with W |
Titanium finish | replace B with C49 |
Integral 3 hour duration emergency | add suffix /EM3 |
Self test 3 hour duration emergency | add suffix /EM3S |
DALI 3 hour duration emergency* | add suffix /EM3D |
DALI dimming/monitoring | add suffix /DALI |
Warm white LEDs (3000K) | replace NW with WW |
Switch dimming | add suffix /DIM |
For 30/60° version | replace D883 with D882 |
Blank ends | add suffix /BE |
For Network Rail specification | add suffix /NET |
Anti Graffiti Diffuser Upgrade | add suffix/ AGD |
For use with 110V ac/dc central battery systems | add suffix /EV |
240V changeover relay | add suffix /ER |
* EM3D not available on all 2 foot (700mm) versions.