Transport Products

Showing 33–48 of 57 results

Technical Information

The data below is for the 45° angled luminaire (D893). A 30°/60° angled luminaire is also available (D892). The lamp data is identical except that the weight of the 30°/60° angled luminaire (D892) is as follows: 650mm = 4.8kg, 1250mm = 8.6kg, 1600mm = 10.7kg.

L650mm x W121mm x H121mm
LED, Opal Diffuser Temp Load Lum/lm Efficacy CRI Weight
D893/2/2000NW/XB 4000K 18.6W 1749 lm 94lm/W CRI>80 4.3kg
D893/2/2500NW/XB 4000K 22.8W 2108 lm 93lm/W CRI>80 4.3kg
D893/2/3000NW/XB 4000K 26W 2376 lm 91lm/W CRI>80 4.3kg
Emergency Output 4000K 457 lm
L1250mm x W121mm x H121mm
LED, Opal Diffuser Temp Load Lum/lm Efficacy CRI Weight
D893/4/2000NW/XB 4000K 21W 2220 lm 105lm/W CRI>80 8kg
D893/4/3000NW/XB 4000K 27.5W 2863 lm 104lm/W CRI>80 8kg
D893/4/4000NW/XB 4000K 34.5W 3382 lm 98lm/W CRI>80 8kg
D893/4/5000NW/XB 4000K 42.1W 4021 lm 95lm/W CRI>80 8kg
D893/4/6000NW/XB 4000K 49W 4546 lm 93lm/W CRI>80 8kg
Emergency Output 4000K 576 lm
L1550mm x W121mm x H121mm
LED, Opal Diffuser Temp Load  Lum/lm Efficacy CRI Weight
D893/5/2500NW/XB 4000K 25.7W 2720 lm 106lm/W CRI>80 10kg
D893/5/3750NW/XB 4000K 34.1W 3503 lm 103m/W CRI>80 10kg
D893/5/5000NW/XB 4000K 47W 4667 lm 99lm/W CRI>80 10kg
D893/5/6250NW/XB 4000K 52.2W 5067 lm 97lm/W CRI>80 10kg
D893/5/7500NW/XB 4000K 61.3W 5720 lm 93lm/W CRI>80 10kg
Emergency Output 4000K 724 lm

Tuscan 89 Angled contains a light source of energy efficiency class C (4000K) and class D (3000K).

Tuscan 89 Angled LED Lifetime L70B10>110,000h (4000K), L70B10>100,000h (3000K) at 25oC ambient.

Tuscan 89 Angled Driver Lifetime up to 100,000h at 25oC ambient.

Fitting Options

Textured white finish replace B with W
Titanium finish replace B with C49
Integral 3 hour duration emergency add suffix /EM3
Self test 3 hour duration emergency add suffix /EM3S
DALI 3 hour duration emergency* add suffix /EM3D
DALI dimming/monitoring add suffix /DALI
Warm white LEDs (3000K) replace NW with WW
Switch dimming add suffix /DIM
For 30/60° angled version replace D893 with D892
Blank ends add suffix /BE
For Network Rail specification add suffix /NET
Corridor function** add suffix /CF10
Anti Graffiti Diffuser Upgrade add suffix /AGD
For use with 110V ac/dc central battery systems add suffix /EV
240V changeover relay add suffix /ER

* EM3D not available on all 2 foot (650mm) versions.

** CF10 option available will only work if combined with an external presence detection sensor supplied by others.

References